Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clinics ; 71(2): 69-72, Feb. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-774535

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the accuracy of Spot Vision ScreeningTM as an autorefractor by comparing refraction measurements to subjective clinical refractometry results in children and adult patients. METHODS: One-hundred and thirty-four eyes of 134 patients were submitted to refractometry by Spot and clinical refractometry under cycloplegia. Patients, students, physicians, staff and children of staff from the Hospital das Clínicas (School of Medicine, University of São Paulo) aged 7-50 years without signs of ocular disease were examined. Only right-eye refraction data were analyzed. The findings were converted in magnitude vectors for analysis. RESULTS: The difference between Spot Vision ScreeningTM and subjective clinical refractometry expressed in spherical equivalents was +0.66±0.56 diopters (D), +0.16±0.27 D for the vector projected on the 90 axis and +0.02±0.15 D for the oblique vector. CONCLUSIONS: Despite the statistical significance of the difference between the two methods, we consider the difference non-relevant in a clinical setting, supporting the use of Spot Vision ScreeningTM as an ancillary method for estimating refraction.


Assuntos
Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Refração Ocular , Erros de Refração/diagnóstico , Testes Visuais/instrumentação , Testes Visuais/métodos
2.
São Paulo; s.n; 2015. [98] p. ilus, tab, graf.
Tese em Português | LILACS | ID: biblio-870927

RESUMO

INTRODUÇÃO: Aproximadamente 20% das crianças brasileiras em idade escolar apresentam algum problema oftalmológico e cerca de 95% dos distúrbios poderiam ser evitados ou minorados com promoção de saúde e assistência. A triagem visual é realizada por agentes comunitários de saúde, professores e alfabetizadores. Apesar do treinamento que os professores recebem, muitas crianças são dispensadas na triagem realizada nos serviços especializados e ainda existe um alto índice de absenteísmo, evidenciando-se a necessidade de melhorar a gestão dos recursos humanos e financeiros envolvidos no rastreamento visual e refrativo de escolares do ensino fundamental. OBJETIVOS: O estudo buscou comparar o rastreamento visual com corte de acuidade visual monocular, sem correção, <= 0,7, corte <= 0,6, medida de acuidade visual binocular e corte <= 0,7 e rastreamento refrativo com Spot Vision ScreeningTM PediaVision (SPOT). O segundo objetivo deste estudo foi avaliar a performance do SPOT como auto-refrator. MÉTODOS: Durante o Projeto Visão do Futuro, ocorrido em 2012, no HCFMUSP, avaliamos 1554 crianças, que preencheram os critérios de inclusão do estudo e destas, 148 foram submetidas ao photoscreening. RESULTADOS: A adoção de corte <= 0,6 no rastreamento visual monocular reduziria em 29% o número de crianças encaminhadas para avaliação oftalmológica e a triagem binocular com corte <= 0,7 em 41,1%, porém 61 casos de ambliopia deixariam de ser diagnosticados. O SPOT apresentou sensibilidade em detectar erro refracional com necessidade de prescrição de 73,3% e especificidade de 93,18% e, em média, a diferença da refração do Spot com a refração clínica subjetiva foi de + 0,63 DE com -0,33 DC no eixo de 4°, para o olho direito de cada paciente. CONCLUSÕES: As mudanças de corte para 0,6 e binocular 0,7 reduzem consideravelmente o número de avaliações, porém, a última deixa de diagnosticar parcela importante das crianças amblíopes. O SPOT apresentou bons índices de...


BACKGROUND: Approximately 20% of brazilian children of school age have some eye problem and about 95% of the disorders could be prevented or reduced with health promotion and care. The visual screening is performed by community health agent and teachers. Despite training that teachers receive, many children are over-referred and also there's a high index of absence students, highlighting the need to improve the management of human and financial resources involved in visual and refractive screening of elementary school. PURPOSES: The present study aimed to compare visual screening by monocular visual acuity with cut-off of 0,7, 0,6, binocular visual acuity and cut-off 0,7 and photoscreening by Spot Vision ScreeningTM PediaVision (SPOT). The second objective of this study was to evaluate the performance of the Spot as auto-refractor. METHODS: During the Program "Visão do Futuro", in 2012, at HCFMUSP, 1554 children that met the inclusion criteria were examined, 148 of these were photoscreened. RESULTS: The adoption of cut-off <= 0.6 in monocular visual screening would reduce by 29% the number of children referred for ophthalmic evaluation and binocular screening with cutting <= 0.7 to 41.1%, however 61 cases of amblyopia would not be diagnosticated. SPOT had a sensitivity to detect refractive error requiring prescription of 73.3% and specificity of 93.18%. The mean difference between refraction obtained by Spot and clinical subjective refraction was of +0.63 SD combined with -0,33 CD in the 4° axis for right eye of each patient. CONCLUSIONS: Reducing cut-off in monocular visual acuity to 0.6 or 0.7 binocular considerably reduce the number of evaluations, however, the last leaves to diagnose significant portion of amblyopic children. The SPOT showed good levels of sensitivity and specificity in refractive screening of school children and refraction values obtained with this equipment are clinically similar to the values of subjective clinical refraction.


Assuntos
Humanos , Masculino , Feminino , Criança , Criança , Técnicas de Diagnóstico Oftalmológico , Ensino Fundamental e Médio , Refração Ocular , Seleção Visual , Visão Binocular , Visão Monocular , Acuidade Visual
3.
Arq Bras Oftalmol ; 75(1): 38-42, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22552416

RESUMO

PURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. RESULTS: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). CONCLUSIONS: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.


Assuntos
Ambliopia/diagnóstico por imagem , Câmara Anterior/diagnóstico por imagem , Esotropia/diagnóstico por imagem , Cristalino/diagnóstico por imagem , Corpo Vítreo/diagnóstico por imagem , Ambliopia/etiologia , Biometria , Estudos de Casos e Controles , Criança , Pré-Escolar , Topografia da Córnea , Esotropia/complicações , Humanos , Ultrassonografia
4.
Arq. bras. oftalmol ; 75(1): 38-42, jan.-fev. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-622544

RESUMO

PURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. RESULTS: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). CONCLUSIONS: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.


OBJETIVO: Investigar a contribuição individual da profundidade da câmara anterior, da espessura do cristalino e da profundidade da câmara vítrea para o comprimento axial total em pacientes com ambliopia por esotropia. MÉTODOS: Foram incluídas 74 crianças com idade entre 5 e 8 anos, sendo 37 pacientes com ambliopia por esotropia e 37 voluntários sadios (grupo controle). Foi realizado exame oftalmológico completo, incluindo refração sob cicloplegia e ultrassonografia modo A. Foram registrados profundidade da câmara anterior, espessura do cristalino, profundidade da câmara vítrea e comprimento axial total. A contribuição individual de cada componente para o comprimento axial total foi relatada como valor porcentual e teste t de Student pareado foi utilizado para a comparação entre olho amblíope e olho contralateral e entre olho direito e esquerdo no grupo controle. RESULTADOS: Olhos amblíopes, quando comparados aos olhos contralaterais, apresentaram maior contribuição da espessura do cristalino (P=0,001), menor contribuição da profundidade da câmara vítrea (P=0,001) e contribuição semelhante da profundidade da câmara anterior (P=0,434) para o comprimento axial total. A comparação entre olho direito e olho esquerdo no grupo controle mostrou contribuições semelhantes da profundidade da câmara anterior (p=0,620), da espessura do cristalino (P=0,721) e da profundidade da câmara vítrea (P=0,483) para o comprimento axial total. CONCLUSÕES: Este estudo mostrou diferenças entre olhos amblíopes e não amblíopes quando o comprimento axial total é dividido nas contribuições individuais dos seus componentes.


Assuntos
Criança , Pré-Escolar , Humanos , Ambliopia , Câmara Anterior , Esotropia , Cristalino , Corpo Vítreo , Ambliopia/etiologia , Biometria , Estudos de Casos e Controles , Topografia da Córnea , Esotropia/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...